Sea-Bird Electronics SBE 38 Manual de usuario Pagina 83

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 124
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 82
Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2
83
5. In the Start Real-Time Data Acquisition dialog box, click Start.
A. If you selected Begin archiving data immediately or Begin archiving
data when ‘Start Archiving’ command is sent above, and selected
Prompt for Header Information in the Header Form setup (Configure
Outputs), the Header Information dialog box appears. Fill in the
desired header and click OK.
B. If you selected NMEA position data added in the .xmlcon or .con file,
Seasave initializes NMEA communications.
C. If you selected Check Scan Length in the Options menu, Seasave
checks the .xmlcon or .con file to verify that the scan length defined by
the configuration file matches the 19plus V2 (i.e., number of sensors
and inclusion of NMEA is as defined in the file). If a Scan length error
appears, verify that:
You are using the correct .xmlcon or .con configuration file.
The configuration file has been updated as necessary if you added
or deleted sensors, added or deleted NMEA or Surface PAR, etc.
D. Seasave sends a message: Waiting for data. . . If you have already
started logging data, ignore the message; otherwise, slide the
magnetic switch to the On position or apply external power, as
applicable to your setup of the 19plus V2. Seasave times out if data is
not received within Timeout in seconds at startup.
E. Real-time data then starts appearing in the screen displays.
6. To stop real-time data acquisition: In the Real-Time Data menu,
select Stop.
7. Stop logging:
If IgnoreSwitch=N and AutoRun=N: Put the magnetic switch in the
Off position.
If IgnoreSwitch=Y and AutoRun=N: Close Seasave, then open
Seaterm232 and send Stop.
If AutoRun=Y: Remove external power.
Notes:
If in Moored mode, the 19plus V2
must be sampling autonomously to
use Seasave for real-time data
acquisition. Start sampling by
sending StartNow or StartLater in
Seaterm232 before starting
acquisition in Seasave.
To prevent problems in the use of
the COM port, click Disconnect in
the Communications menu in
Seaterm232, and close Seaterm232
before starting real-time acquisition
in Seasave.
Vista de pagina 82