Manual revision 006 Appendix III: Command Summary SBE 19plus V2
110
Appendix III: Command Summary
CATEGORY COMMAND
Status
GetCD
Get and display configuration data (setup
parameters).
Get and display status data.
Get and display calibration coefficients.
Get and display event counter data.
Delete all events in event counter.
Get and display hardware data.
DS
Get and display configuration data (setup parameters)
and status data.
Get and display calibration coefficients.
General
Setup
Set real-time clock month, day, year, hour,
minute, second.
BaudRate=x
x= baud rate (600, 1200, 2400, 4800, 9600, 19200,
38400, 57600, or 115200). Default 9600.
Echo=x
x=Y: Echo characters as you type.
x=N: Do not.
OutputExecutedTag=x
x=Y: Display XML Executing and Executed tags.
x=N: Do not.
BatteryType=x
x=alkaline: Alkaline (or optional lithium) batteries.
x=nicad: Nickel-Cadmium batteries.
x=nimh: Nickel Metal Hydride batteries.
InitLogging
After all previous data has been uploaded, send this
before starting to log to make entire memory
available for recording. If not sent, data stored after
last sample. Equivalent to SampleNumber=0.
SampleNumber=x
x= sample number for last sample in memory. After
all previous data has been uploaded, set to 0 before
starting to log to make entire memory available for
recording. If not reset to 0, data stored after last
sample. SampleNumber=0 is equivalent to
header and cast number for last cast in memory.
Biowiper=x
x=Y: Configuration includes ECO-FL fluorometer
with Bio-Wiper (voltage or RS-232 auxiliary sensor).
QS
Enter quiescent (sleep) state. Main power turned off,
but data logging and memory retention unaffected.
Pressure and
Voltage
Sensor Setup
PType=x
x=1: Strain-gauge pressure sensor.
x=3: Quartz with temperature compensation.
x=Y: Enable external voltage 0. x=N: Do not.
x=Y: Enable external l voltage 1. x=N: Do not.
x=Y: Enable external l voltage 2. x=N: Do not.
x=Y: Enable external l voltage 3. x=N: Do not.
x=Y: Enable external l voltage 4. x=N: Do not.
: Enable external l voltage 5.
: Do not.
RS-232
Sensor Setup
x=Y: Enable SBE 38. x=N: Do not.
WetLabs=x
x=Y: Enable WET Labs RS-232 sensor.
x=N: Do not.
x=Y: Enable GTD. x=N: Do not.
x=Y: Enable dual (2) GTD x=N: Do not.
TGTD
Measure GTD(s), output 1 converted data sample for
each GTD.
SendGTD=command
Command 19plus V2 to send command to GTD and
receive response (command can be any command
x=Y: Enable Aanderaa Optode. x=N: Do not.
SendOptode=command
Command 19plus V2 to send command to Optode
and receive response (command can be any
command recognized by Optode).
See Command
Descriptions in
Section 4: Deploying
and Operating
SBE 19plus V2 for
detailed information
and examples.